DEMONSTRATOR · RIBA STAGE 4 · TECHNICAL DESIGN

Passive House bungalow, land adjacent to 172 Shelford Road

Technical specification, construction details and the Building Regulations full plans package for the twin's design. Items marked Required need input from a manufacturer, engineer, surveyor or the client before submission.

This is a demonstrator. Planning is assumed approved for the bungalow, and the site follows the demonstrator sketch.

Site
Land adjacent to 172 Shelford Road, Gedling, Nottingham NG4 4JJ
Planning
Gedling BC 2024/0465, assumed approved for this bungalow (demonstrator assumption)
Title number
Not yet obtained: order the official copy from HM Land Registry
Plot
Site layout as the demonstrator sketch
Standard
Passive House Classic (PHI); Building Regulations Part L 2021 route if deposited before 24 Mar 2027
Building Control
Gedling Borough Council, full plans via the Planning Portal
Agent / designer
Emperus Architecture · 07738 968951

Before submission

These items change what can be built or how it is approved. Resolve them before the full plans deposit.

Title and boundaries

The title number is not published online. The auction legal pack was not available.

Order the title register and title plan from HM Land Registry online (small fee per document). Check covenants, rights of way and any sewer easement before fixing the layout.

Ground risks: coal mining and radon

Gedling is a former coalfield. Radon potential varies across Nottinghamshire.

Run the Coal Authority interactive map check (a Coal Mining Risk Assessment if the site is in a high-risk area), order a UKradon report for the address, and commission a site investigation for the raft design.

Surface water route

The services sketch takes rainwater to the road sewer. Part H3 requires infiltration first where ground conditions allow.

Do a BRE 365 percolation test. Use a soakaway or permeable paving if it passes, and record Severn Trent's acceptance if not.

Connections and grid

The twin has 7.56 kWp PV, a 10 kWh battery, a 7.4 kW EV charger and a heat pump.

Apply to Severn Trent (new water supply, sewer connection under s106) and to the DNO under G99 for the generation and battery.

MVHR location

The twin places the MVHR unit in the cold loft beside the chimney. Passive House practice keeps the unit inside the thermal envelope.

Either build an insulated, airtight enclosure in the loft or move the unit into the utility, keeping the cold intake and exhaust ducts short and insulated with 50 mm closed-cell lagging.

Passive House targets

PHI Passive House Classic criteria, set against the twin's first-pass estimate. Certification needs a PHPP model, the as-built details and a blower-door test.

CriterionPHI limitTwin estimateStatus
Space heating demand≤ 15 kWh/m²a≈ 16Refine in PHPP
or heating load≤ 10 W/m²≈ 14Refine in PHPP
Airtightness n50≤ 0.6 h⁻¹design 0.6Test at first fix and completion
Primary energy renewable (PER)≤ 60 kWh/m²aheat pump + PVPHPP
Overheating frequency (> 25 °C)≤ 10 % (target 5 %)not yet assessedRequired
Opaque U-values≈ 0.10–0.15walls 0.10, roof 0.09, floor 0.10Specified
Windows installedUw,inst ≤ 0.85Uw 0.80, ψ-install ≤ 0.04Specified
MVHR heat recovery≥ 75 % (PHI)≥ 90 %Specified

To close the gap: Uw 0.75 windows, 320 mm EPS on walls, 92 % MVHR and optimised south glazing bring the estimate to about 14 kWh/m²a. The bungalow form and attached garage make compactness the main challenge.

Construction details

Key thermal-bridge-free junctions at 1:10, schematic. Numbered callouts match the notes. Final details follow the raft supplier's, window manufacturer's and truss manufacturer's standard details.

Element build-ups

Specification by element, outside to inside. Products are named by type; equivalent certified products may be used if they meet the same performance.

Structural design responsibility

Structural calculations come from the manufacturers and the engineer named below. Building Control can approve with conditions, with the calculations deposited before each element starts on site.

ElementDesigned byStandardTo submitStatus
Insulated raft foundationRaft system supplier's engineerBS EN 1992-1-1, BS EN 1997-1Raft calculations and drawings based on the site investigation, edge and thickening details, reinforcement scheduleRequired
Prefabricated trussed rafters, 25° hipTruss manufacturer (TRA member)BS EN 1995-1-1, BS 8103-3Truss and girder calculations, layout, hip set, bracing, hangers, loads incl. PV and loft plantRequired
Lintels and the 4.0 m bi-fold openingLintel manufacturer / structural engineerBS EN 1993-1-1, BS EN 845-2Lintel schedule, steel beam or goalpost with thermally broken padstonesRequired
Masonry walls and restraintStructural engineerBS EN 1996-1-1, BS 8103-2Wall panel and wind check, strapping to trusses at 2 m centresRequired
EWI fixingsEWI system holderETA / BBA certificateFixing pattern for wind load and exposure, fire classificationRequired
PV mounting on the roofMCS installer + truss manufacturerMCS 012Roof load check and fixing designRequired
Retaining walls (sloping plot)Structural engineerBS EN 1997-1Only if the survey shows level changes need themIf needed

Building Regulations compliance, Parts A–S

How the design meets each Approved Document and the evidence to deposit with the full plans application.

PartHow the design compliesEvidenceStatus

Full plans application

The content for Gedling's full plans form, ready to transfer into the Planning Portal or the LABC form. Fields marked "to confirm" need the client's details.

24 Mar 2027Deposit full plans before this date to stay under Part L 2021 instead of the Future Homes Standard
24 Mar 2028Foundations and ground-floor structure must be complete by then for that transition to hold
2 daysMinimum notice before starting work: send a commencement notice to Building Control
3 yearsApproval lapses if work has not started within three years of deposit

Application

Authority
Gedling Borough Council, Building Control
Route
Planning Portal, or the LABC Full Plans form from Gedling's website. Payment by phone on 0115 901 3740, online or BACS.
Type
Full plans (recommended for a new dwelling)
Site address
Land adjacent to 172 Shelford Road, Gedling, Nottingham NG4 4JJ
Description
Erection of a single-storey three-bedroom detached dwelling with integral garage to Passive House standard: insulated raft foundation, external wall insulation on dense blockwork, prefabricated trussed rafter roof, MVHR, air-to-water heat pump with underfloor heating, 7.56 kWp PV with 10 kWh battery, and EV charge point.
Use
Dwellinghouse (C3), one storey, GIA 185.78 m²; not a higher-risk building
Planning
2024/0465, approved for a single-storey dwelling (demonstrator assumption)
Water and drainage
Mains water (Severn Trent). Foul to public sewer. Surface water to soakaway or SuDS subject to percolation test.
Conditions
Consent to approval with conditions for the structural calculations listed above
Fee
Plan and inspection charge for one new dwelling from Gedling's current charges; confirm with Building Control

Dutyholders and declarations

Required with every full plans application in England since 1 October 2023.

Client
Plot owner (company) To confirm
Principal designer
Emperus Architecture, proposed Client to appoint in writing
Principal contractor
To be appointed To confirm
Agent
Emperus Architecture · 07738 968951 · emperusgroup@gmail.com
Statements
Client's statement on the competence of the appointed dutyholders; statement that the building is not higher-risk; description of the work and its compliance
Competent persons
Electrical (Part P), heat pump and unvented cylinder (G3), MVHR commissioning (Part F) and PV (MCS) self-certified by registered installers
After approval
Commencement notice, staged inspections, airtightness test, as-built SAP/EPC and BREL, then the completion certificate

Document register

What the full plans package needs and where each item stands. Twin items are already in this website.

DocumentSourceStatus

Sources: Pugh Auctions, Lot 292 (plot size, planning ref and date) · Gedling BC, apply for building regulation approval · Future Homes Standard transitional dates. This page is design guidance prepared in the twin; it is not a Building Control decision.